Hantek DSO4072C Oscilloscope 2 canaux 70MHZ et générateur AWG

362.69 €
435,23 € TVA INCLUSE

Oscilloscope avec bande passante de 70 MHz.
Taux d'échantillonnage de 1GSa / s.
Générateur de signaux arbitraires de 25 MHz, résolution 12 bits, DDS 200 MHz.
2 canaux d'oscilloscope.
1 canal générateur de signaux / fonctions arbitraires.
Commandes séparées pour l'oscilloscope et le générateur permettant une utilisation simultanée confortable.
Écran couleur 64K et 7 pouces, avec une résolution de 800x480.
Poignée et jambes pliables pour un transport facile.

Quantité
Expédition en 48/72 heures

Hantek DSO4072C  Oscilloscope 2 canaux 70MHZ et générateur AWG

Feature:

  • 2 Channel Digital Oscilloscope + Arbitrary/Function Waveform Generator +Synchronizing Signal + External Trigger
  • The Keys for osilloscope and waveform generator is seperated for convenient to operate it simultaneously;
  • Large and clear display (7 inch 64K color LCD display, Resolution 800x480), more clear and realistic waveform;
  • Oscilloscope: 1GSa/s Sample Rate, 200/100/70MHz Bandwidth, more than 20 kinds of auto measurement functions;
  • Powerful Trigger Function: Edge, Video, Pulse, Slope, Over time, Alternative;
  • Arbitrary/Function Waveform Generator: 25MHz, 12 bits resolution, 200MHz DDS, Arbitrary wave/square wave/sine wave/triangle wave/trapezoidal wave/pulse wave/DC is easy to simulate transducer.
  • Support SD card, VGA function (optional);
  • Integrated USB Host, Support USB disk storage, USB interface/SD card system update.


ModelDSO4202CDSO4102CDSO4072C
Oscilloscope
Sample RateSampling Rate Range: 1GSa/s
Equivalent Sample Rate: 25GSa/s
Acquisition Modes
NormalNormal data only
Peak DetectHigh-frequency and randon glith capture
AverageWavefom Average, selectable 4,8,16,32,64,128
Inputs
Inputs CouplingAC, DC, GND
Inpits Impendance1MΩ±2% ‖20pF±3pF
Probe Attenuation1X, 10X
Supported Probe Attenuation Factor1X, 10X, 100X, 1000X
Maximum Input VoltageCAT I and CAT II: 300VRMS (10×)
CAT III: 150VRMS(1×);
Installation Category II: derate at 20dB/decade above 100kHz to 13V peak AC at 3MHz* and above. For non-sinusoidal waveforms, peak value must be less than 450V. Excursion above 300V should be of less than 100ms duration. RMS signal level including all DC components removed through AC coupling must be limited to 300V. If these values are exceeded, damage to the oscilloscope may occur.
Horizontal
Sample Rate Range1GS/s
Waveform Interpolation(sin x)/x
Record Length40K
SEC/DIV Range2ns/div to 40s/div
Sample Rate and±50ppm(at over any ≥1ms time interval)
Delay Time Accuracy
Position Range

2ns/div to 8ns/div;

(-8div x s/div) to 20ms;

20ns/div to 80us/div; (-8div x s/div) to 40ms;
200us/div to 40s/div; (-8div x s/div) to 400s
Vertical
Vertical Resolution8-bit resolution, all channel sampled simultaneously
Position Range2mV/div to 10V/div
Bandwidth200MHz100MHz70MHz
Rise Time at BNC( typical)1.8ns3.5ns5ns
Math+, -, *, /, FFT
FFTWindows: Hanning, Flatop, Rectamgular, Bartlett, Blackman;
1024 sample point
Bandwidth Limit20MHz
Low Frequency Response (-3db)≤10Hz at BNC
DC Gain Accuracy±3% for Normal or Average acquisition mode, 10V/div to 10mV/div;
±4% for Normal or Average acquisition mode, 5mV/div to 2mV/div
DC Measurement Accuracy,
Average Acquisition Mode
When vertical displacement is zero, and N 16:± (3% × reading + 0.1div + 1mV) only 10mV/div or greater is selected;
When vertical displacement is not zero, and N
16: ± [3% × (reading + vertical position) + 1% of vertical position + 0.2div]; Add 2mV for settings from 2mV/div to 200mV/div; add 50mV for settings from 200mV/div to 10V/div
Volts Measurement Repeatability, Average Acquisition ModeDelta volts between any two averages of ≥16 waveforms acquired under same setup and ambient conditions
Trigger System
Trigger TypesEdge, Video, Pulse, Slope, Over time, Alternative
Trigger SourceCH1, CH2, EXT, EXT/5, AC Line
Trigger ModesAuto, Normal, Single
Coupling TypeDC, AC, Noise Reject, HF Reject, LF Reject
Trigger Sensitivity
(Edge Trigger Type)
DC(CH1,CH2):
1div from DC to 10MHz; 1.5div from 10MHz to 100MHz; 2div from 100MHz to Full;
DC(EXT):
200mV from DC to 100MHz; 350mV from 100MHz to 200MHz;
DC(EXT/5):
1V from DC to 100MHz;1.75V from 100MHz to 200MHz;
AC: Attenuates signals below 10Hz;
HF Reject: Attenuates signals above 80kHz;
LF Reject: Same as the DC-coupled limits for frequencies above 150kHz; attenuates signals below 150kHz
Trigger Level RangeCH1/CH2: ±8 divisions from center of screen;
EXT: ±1.2V;
EXT/5:±6V
Trigger Level Accuracy( typical)Accuracy is for signals having rise and fall times ≥20nsCH1/CH2: 0.2div × volts/div within ±4 divisions from center of screen;
EXT: ± (6% of setting + 40mV);
EXT/5: ± (6% of setting + 200mV);
Set Level to 50%(typical)Operates with input signals ≥50Hz
Video Trigger
Video Trigger TypeCH1, CH2: Peak-to-peak amplitude of 2 divisions;
EXT: 400mV;
EXT/5: 2V
Signal Formats and Field Rates, Video Trigger TypeSupports NTSC, PAL and SECAM broadcast systems for any field or any line
Holdoff Range100ns ~ 10s
Pulse Width Trigger
Pulse Width Range20ns ~ 10s
Slope Trigger
Slope Trigger ModeTrigger when (< , > , = , or ≠ ); Positive slope or Negative slope
Slope Trigger PointEqual: The oscilloscope triggers when the waveform slope is equal to the set slope.
Not Equal: The oscilloscope triggers when the waveform slope is not equal to the set slope.
Less than: The oscilloscope triggers when the waveform slope is less than the set slope.
Greater than: The oscilloscope triggers when the waveform slope is greater than the set slope.
Time Range20ns ~ 10s
Overtime Trigger
Over Time ModeRising edge or Falling edge
Time Range20ns ~ 10s
Alternative Trigger
Trigger on CH1Internal Trigger: Edge, Pulse Width, Video, Slope
Trigger on CH2Internal Trigger: Edge, Pulse Width, Video, Slope
Trigger Frequency Counter
Readout Resolution6 digits
Accuracy (typical)±30ppm (including all frequency reference errors and ±1 count errors)
Frequency RangeAC coupled, from 4Hz minimum to rated bandwidth
Signal SourcePulse Width or Edge Trigger modes: all available trigger sources
The Frequency Counter measures trigger source at all times, including when the oscilloscope acquisition pauses due to changes in the run status, or acquisition of a single shot event has completed.
Pulse Width Trigger mode: The oscilloscope counts pulses of significant magnitude inside the 1s measurement window that qualify as triggerable events, such as narrow pulses in a PWM pulse train if set to < mode and the width is set to a relatively small time.
Edge Trigger mode: The oscilloscope counts all edges of sufficient magnitude and correct polarity.
Video Trigger mode: The Frequency Counter does not work.
Measure
Cursor MeasurementVoltage difference between cursors: △V
Time difference between cursors: △T
Reciprocal of △T in Hertz (1/ΔT)
Auto MeasuermentFrequency, Period, Mean, Pk-Pk, Cycli RMS, Minimum, Maximum, Rise time, Fall Time,
+Pulse Width, -Pulse Width, Delay1-2Rise, Delay1-2Fall, +Duty, -Duty, Vbase, Vtop, Vmid,
Vamp, Overshoot, Preshoot, Preiod Mean, Preiod RMS, FOVShoot, RPREShoot, BWIDTH,
FRF, FFR, LRR, LRF, LFR, LFF
Signal Source Mode
Waveform ImpedanceDC-25MHz
Sample Rate200MHzDDS
Output WaveformArbitrary wave/square wave/sine wave/triangle wave/trapezoidal wave/pulse wave/DC
Frequency Resolution0.1%
Waveform Depth2KSa
Vertical Resolution12bit
Frequency Stability<30ppm
Waveform Range-3.5V~+3.5V
Output Impedance50Ω
Output Current50mA Ipeak=50mA
System BW25M
Harmonic Distortion-50dBc(1KHz),-40dBc(10KHz)
General Features
Display
Display Type7 inch 64K color TFT (diagonal liquid crystal)
Display Resolution800 horizontal by 480 vertical pixels
Display ContrastAdjustable (16 gears) with the progress bar
Probe Compensator Output
Output Voltage( typical)About 5Vpp into ≥1MΩ load
Frequency(typical)1kHz
Power Supply
Supply Voltage100-120VACRMS(±10%), 45Hz to 440Hz, CATⅡ
120-240VACRMS(±10%), 45Hz to 66Hz, CATⅡ
Power Consumption<30w td="">
Fuse2A, T rating, 250V
Environmental
TemperatureOperating: 32℉ to 122℉ (0℃ to 50℃);
Nonoperating: -40℉ to 159.8℉ (-40℃ to +71℃)
Cooling MethodConvection
Humidity+104℉ or below (+40℃ or below): ≤90% relative humidity;
106℉ to 122℉ (+41℃ to 50℃): ≤60% relative humidity
AltitudeOperating: Below 3,000m (10,000 feet);
Nonoperaring: Below 15,000m(50,000 feet)
Mechanical
SizeLength 385mm, Width 200mm, Height 245mm
Weight3.5KG(with Packing); 2.08KG(without Packing)
HANTEK
DSO4072C

Fiche technique

Canaux d'oscilloscope
2
Bande passante de l'oscilloscope
70
Serie
DSO4002C
Générateur de signal / Fonctions
Oui

Références spécifiques

Téléchargement

Pour télécharger ces fichiers, vous devez avoir acheté le produit auparavant et être connecté à votre compte.

(FR) Manuel basique

Manuel basique de sécurité et de démarrage - French

Téléchargement (159.77KB)

(EN) Manual abbreviated

Basic Safety Manual and Startup - English

Téléchargement (158.8KB)

(EN) DSO4000BC Manual

DSO4000BC Extended Manual (English)

Téléchargement (2.19MB)